REF · med-usb-c-patient-cable
Medical USB-C Device Cable with Project-Defined Power and Data

Product Overview
This USB-C cable is built only after both device interfaces, pin assignment, negotiated data mode, power role, shield plan and strain relief are fixed in the controlled drawing. Patient-contact classification, cleaning exposure and electrical safety acceptance belong to the finished medical-device program.
Application Scenarios
- Patient monitoring, diagnostic, imaging and portable medical equipment
- Sensor leads, probe extensions, internal medical harnesses and patient-side cable programs
- Replacement or compatible cable development based on drawings, samples or device interfaces
- Projects that require stable labeling, traceability and repeat-order control
Custom Options
- Connector interface, length, jacket material, color and labels can be customized
- TPU, silicone, shielding, overmolding and strain-relief structures can be reviewed per device context
- Samples can be matched to patient-side, probe-side or host-side interface definitions
- Documentation and inspection plans can be aligned with the target medical device program
Standards and Evidence Boundary
IEC 60601-1, IEC 60601-1-2, applied-part classification, biocompatibility and cleaning or sterilization claims are included only when the customer supplies the applicable device requirements and validation evidence. Material declarations can be prepared against the selected cable BOM; they do not certify the cable or the finished medical device.
RFQ Inputs & Material Requirements
Provide both connector and device references, pin assignment, data mode and power profile, cable construction, shield and ground plan, finished length and route, strain relief, cleaning inputs, material requirements and device-defined electrical, EMC and mechanical tests.
Technical Specifications
SPECIFICATIONS · 12 ROWS
- 01Connector Interface
- Exact USB-C plug, receptacle and device references from the approved BOM
- 02USB Data Mode
- Defined by the device architecture and validated on the finished link
- 03Power Role and Rating
- Customer-specified source, sink and negotiated power profile
- 04Conductor Assignment
- Gauge, plating and pair construction selected from current, data and flex requirements
- 05Insulation and Jacket Materials
- Exact material grades from the approved BOM and evidence package
- 06Finished Outer Diameter
- Controlled drawing value after cable-construction review
- 07Temperature Exposure
- Project-defined operating, storage and cleaning profile
- 08Cleaning / Sterilization Exposure
- Named agents, concentration, temperature, pressure and cycle count supplied by the device program
- 09Patient-Contact and Safety Boundary
- Applied-part classification and leakage-current limits supplied by the device manufacturer
- 10Mechanical Acceptance
- Pull, bend and strain-relief methods and limits defined in the validation plan
- 11Finished Length
- Controlled drawing dimension and tolerance
- 12Jacket and Identification Color
- Approved BOM, label and traceability scheme
Applications
PILLARSee how the Medical Cable Assemblies family fits real projects.
Open Application Page